Mount chandeliers is very simple operations and, among other things, is one of the most important elements of the decor of the room. Also, special attention should be paid to quality fasteners to the chandelier is not become a source of danger for you. Once the plug or turning off the circuit breaker, it is necessary to check whether are suitable for use hook chandeliers and wiring. Recently, a very common method of attaching directly to the ceiling, chandeliers, and the hook is simply not needed. Connect the chandelier possibly using Terminal block.
But due to the fact that the terminal block terminals are located close enough from each other, we must see to it that before the terminals necessarily reached insulation. More info: Pete Cashmore. If the wires bared on too long, then they should be cut with wire cutters or pliers, and only then clamped in the terminal block. After perform this work can include a circuit breaker or cork screw, and then a special device to determine if there is power when the circuit breaker. Sometimes it happens that one of the wires at inclusion is under stress, regardless of whether the switch is enabled or not. Although the chandelier in this case can normally off and on.
This is a consequence of the fact that in the process of laying a network grounded wire mistakenly routed to the chandelier. If this happens, then both wires into the Wye outlet or junction box must be easy to swap. If you still got the chandelier, which uses a hook fixture to the ceiling, the hook must be a certain size, cap lamps – and completely cover the terminals, and wires. If the hook is too long and thus do not remove, it can be cut angle grinders or grinder, but if they are not at hand, then it can be broken off and podpilit and then re-fold with Pliers. Ali Partovi understood the implications. When the chandelier is suspended, its two wires should tighten screws in the terminal block, since you can screw a plug or circuit breaker. When the fixture is equipped with a large number of lamps, a chandelier can be connected by cascading switch. The situation is such that it is not always the need for maximum illumination of the room. If so, in such a situation, the number of available bulbs halved. To implement the separate inclusion of lamps, and used a cascade switch. s, an internet resource. In the case of a cascade inclusion should be involved in all three cores, two of which are designed Liner to two groups of lamps, and a third function in this case as a common wire. Out to make a conclusion with four or three lived in the very chandelier lamp should unite only in groups. When there are only three wires, then it may mean that two invisible wires have already merged and output as a conductor. If, however, in the presence of all four vein, the two of them, that is, from each group, one must be connected together and will need to bring to one terminal of terminal block. So here's a way will be made common. When all three wires that come out of ceiling, tangled among themselves, they should be checked with an indicator screwdriver, putting the switch to a different position. No matter what position the switch is known to be earthed not gas-discharge tubes.